The Analyses on Hysteretic Performance of K-type Node in Large Span Steel Tubular Tower

Liu Chuncheng, Li Guoqiang, Fan Xiaoling, Mao Long, Long Zuliang, Zha Chuanming

PDF(7642 KB)
PDF(7642 KB)
Journal of Northeast Electric Power University ›› 2017, Vol. 37 ›› Issue (6) : 79-85.

The Analyses on Hysteretic Performance of K-type Node in Large Span Steel Tubular Tower

  • Liu Chuncheng1, Li Guoqiang1, Fan Xiaoling1, Mao Long1, Long Zuliang1, Zha Chuanming2
Author information +
History +

Abstract

This paper used Abaqus software to make numerical experimental studies on the seismic performance of the common K-type node in large span steel tower.It analyzed different parameters of the pipes diameter,axial pressure of the main pipe,thickness of the connection plate and gap dimension.At last,it obtained the hysteresis curves,skeleton curves and energy dissipation capacity,received the influence of these parameters on seismic performance of the node.Research shows that the steel pipe node itself has a good seismic performance.When the axial pressure increases,the seismic performance is significantly decreasing.The node prone to fail because of stress concentration.Increasing the main and branch pipe diameter and node plate thickness all can significantly improve the seismic performance the node.The effect of branch pipe gap size on node hysteretic performance improvement is not obvious.

Key words

K-type node of steel tube tower / Numerical simulation / Pseudo-static experiment / Parameter analysis / Hysteretic performance

Cite this article

Download Citations
Liu Chuncheng, Li Guoqiang, Fan Xiaoling, Mao Long, Long Zuliang, Zha Chuanming. The Analyses on Hysteretic Performance of K-type Node in Large Span Steel Tubular Tower. Journal of Northeast Electric Power University. 2017, 37(6): 79-85

References

[1] 刘春城,龙祖良,景欢,等.考虑桩-土-结构相互作用的输电塔风振响应分析[J].东北电力大学学报,2016,36(6):84-90.

[2] 刘春城,刘法栋,毛绪坤,等.高压输电塔县体系覆冰的研究现状与展望[J].东北电力大学学报,2011,31(5/6):17-22.

[3] 邓洪洲,傅俊涛.大跨越钢管塔节点强度理论与试验研究[D].上海:同济大学,2006:33-54.

[4] 郭耀杰,徐芸.大跨越高压输电线路高耸塔高强钢钢管节点研究[D].武汉:武汉大学,2009:19-30.

[5] J.M.Goggins,B.M.Brodericka,A.Y.Elghazouli,et al..Behavior of tubular steel members under cyclic axial loading[J].Journal of Constructional Steel Research,2006,62(l/2):121-131.

[6] 陈以一,沈祖炎,翟红,等.圆钢管相贯节点滞回特性的实验研究[J].建筑结构学报,2003,24(6):57-62.

[7] 武振宇,高洋.K型间隙方管节点滞回性能的有限元分析[J].低温建筑技术,2009,31(l):32-34.

[8] 武振宇,张扬,何小辉,等.Y形直接焊接矩形钢管节点滞回性能试验研究[J].建筑结构学报,2010,31(8):63-70.

[9] 刘春城,李文强,高培国,等.特高压直流输电塔多尺度模拟与节点分析[J].科学技术与工程,2014,14(33):229-233.

[10] 蔡艳青,邵永波.环口板加强型T型圆钢管节点滞回性能研究[J].土木工程与管理学报,2011,28(3):322-327.

[11] 中华人民共和国住房和城乡建设部.JGJ101/T-2015建筑抗震试验方法规程[S].北京:中国建筑工业出版社,2015.

[12] 李涛,邵永波.主管壁加厚方钢管T型节点滞回性能研究[J].建筑结构学报,2011,32(4):142-150.
PDF(7642 KB)

146

Accesses

0

Citation

Detail

Sections
Recommended

/